Restricted Area · Credential-Locked · Caffeine Crystallization

Method 5 · Plates.
Colour without dyes.

← All chemistry guides
cc-plates.html

Method 5 — Hexagonal Plates

Acetone/water · 🧪 experimental · Yield 70–80% · ~24–36 hr · Medium

Principle

Acetone parks on the prism faces ({100}/{010}) and slows them down — the mirror image of Method 2's trick. Now the basal face wins, so crystals come out thin and flat, perpendicular to the c-axis: hexagonal plates with dramatic interference colours under backlight.

Solvent systems

  • System A (primary): 70/30 acetone/water by volume — most reproducible. 50/50 gives thinner, more fragile plates; 30/70 sits in a blades→plates transition zone.
  • System B: water + 0.1% urea (0.1 g per 100 mL) — urea incorporates at the prism faces; slightly hazy plates.
  • System C: water + 0.1% benzoic acid — co-crystallises at the prism faces.

The math (System A)

Total solvent mL = crude grams × 3.2 · at 70/30: acetone = 70% of that, water = 30% · heat to 56 °C (acetone bp), NOT 92 °C

  • 2.5 g → 8 mL (5.6 + 2.4) · 3.0 g → 9 mL (6.3 + 2.7) · 3.5 g → 10 mL (7.0 + 3.0)

Steps (System A)

  1. Heat the solvent to 56 °C in a water bath — acetone boils at 56 °C, never exceed it. Microwave in 10 s bursts, swirl, check temperature.
  2. Dissolve: add crude, stir 30 s, add hot solvent dropwise to clarity, hot-filter into a pre-warmed borosilicate jar.
  3. Seed at 40 °C (optional but recommended): a plate from a previous run, or one scratch on the jar wall.
  4. Deep sleep 24 hr (longer than water — growth is slower), then fridge 4–12 hr at 4 °C (12 hr for thicker plates).
  5. Harvest: pour off mother liquor, rinse with 2–3 mL ice-cold 70/30, separate plates with tweezers (they stick together), air-dry 2 hr — acetone flashes off fast.

Acetone safety (not optional)

  • Highly flammable (bp 56 °C, lower explosive limit 2.5%). No flames, no ignition sources, ventilate, water-bath heating only.
  • Nitrile gloves (skin absorption), safety glasses. Borosilicate jars, loose foil+pinhole covers — never sealed.

Read the result

  • 70/30 → hexagonal plates, 3–8 mm, ~0.03–0.05 mm thick, clear.
  • Backlit, plates throw Newton's-ring interference colours — the best wow-per-hour of the series.
  • Handle by the edges only; they're more fragile than blades.

After the methods: display & preservation, or what not to do (pure acetone gives oil, for one).

Reference material, not professional training, not medical advice. Work with appropriate ventilation and personal protection; double-check everything yourself.

⚗️

Chemistry Guides

Restricted area. Sign in with credentials issued from the admin panel to continue.

Need access? Ask the admin to issue you a read-only login.